Firmware Updates and Release Notes

Commercial Inverters (with SetApp)

Latest Firmware Version: 4.18.514

Release Date: April 2023

This release supports Three Phase Commercial Inverters and Three Phase Commercial Inverters with Synergy Technology.

Released Firmware Version

Products CPU DSP1 DSP2 Additional
Three Phase Commercial Inverter 4.18.514 1.13.2115 2.19.1700  
Three Phase Commercial Inverter with PNs SExxK-xxxxIxxxx 4.18.514 1.20.1518 2.20.1200  
Three Phase Commercial Inverter with Synergy Technology 4.18.514 1.13.2115 2.19.1700  
Three Phase Commercial Inverter with
Synergy Technology: PNs SExxK-xxxxIxxxx
4.18.514 1.20.1518 2.20.1200 Synergy Manager:
0.3.7 / 1.0.8

 

New Features and Enhancements

  • Updated Japan Grid Codes for the new 25kW Commercial Three Phase Inverters: SE25K-JPI3IBNM4, SE25K-JPI6IBNM4
  • South Africa Grid Codes Frequency Start Parameter was modified to comply with grid code requirements, to avoid issues during commissioning or after a grid event
  • Lithuanian grid protection settings are now supported
  • Poland Grid Codes were updated
  • Uruguay country code was updated to comply with new reconnection time regulations
  • Tan phi change was implemented for all French Grid Codes in low voltage range (up to 500 kVA) to comply with new regulations

Known Issues and Limitations

  • Regarding the central settings (Leader inverter with Follower inverters), in some cases the country, grid and power values are not updated in the Follower inverters
    • Workaround: Try to configure the settings again
  • There is an error in the power limit display for the Three Phase Inverters with Synergy Technology (up to 120kW) during slow ramp up after a single Synergy Unit trips

     

Firmware Version: 4.17.615

Release Date: January 2023

This release supports all SetApp-enabled Three Phase Commercial Inverters and Three Phase Commercial Inverters with Synergy Technology.
 

Released Firmware Version

Products CPU DSP1 DSP2 Additional
Three Phase Commercial Inverter 4.17.615 1.13.2018 2.19.1602  
Three Phase Commercial Inverter with
PNs SExxK-xxxxIxxxx 
4.17.615 1.20.1230 2.20.906  
Three Phase Inverter with Synergy Technology 4.17.615 1.13.2018 2.19.1602  
Three Phase Inverter with Synergy Technology
(up to 120kW) with PNs SExxK-xxxxIxxxx
4.17.615 1.20.1230 2.20.906 Synergy Manager:
0.3.7 / 1.0.8

 

New Features and Enhancements

  • Firmware upgrades during site visits is now optional for inverters that were already commissioned and not connected to an Energy Meter. 
    • After connecting to the inverter using SetApp, if a new firmware version is available you may decide to delay the upgrade to a later time by tapping Skip Upgrade
    • Note: SolarEdge recommends upgrading inverter firmware whenever a new version is released
  • The SolarEdge Sense Connect feature is now supported on Three Phase Commercial Inverters and Three Phase Inverters with Synergy Technology, with DSP1 1.20.xxxx and DSP2 2.20.xxxx
    • Sense Connect enhances system safety through early detection and prevention of potential electric arcs at the connector level due to improper connections or possible malfunctions resulting from wear and tear
  • For ROW (i.e. all regions outside of Europe and North America), the ability to toggle the inverter fixed string voltage between 750V and 850V  is now supported via SetApp for the SE33.3K, SE66.6K and SE100K commercial inverters
    • Enables improved design flexibility with fewer strings, less cables/fuses and reduced BoS costs
    • Relevant for installations connected to the S1200 Commercial Power Optimizer, and only for specific inverter part numbers
    • Read this App Note to learn how to toggle the inverter fixed string voltage
  • For European countries, the FCR-D-Down capability was added for Three Phase Commercial Inverters with SE DSP. Controlled and managed by Grid Services.

Known Issues and Limitations

  • Three Phase Inverters with Synergy Technology (up to 120kW): Resetting the inverter during the Pre-Commissioning stage will shut down the system if the inverter is solar powered and a power bank is not connected
    • Workaround: If a reset is required, reconnect the power bank before resetting