SetApp Enabled Inverter: Firmware Updates and Release Notes

  • For Residential inverters, see below
  • For Commercial inverters, click here
  • For inverters with a display click here

 

Firmware Updates- Residential

Version Date - December 2022

Firmware for all SetApp-enabled inverters as well as supported devices and batteries was released in December 2022. Here are the details:

Inverter Firmware

The CPU version for all SetApp-enabled inverters (except for Three-Phase StorEdge inverters) is 4.17.46. The CPU version for Three-Phase StorEdge inverters in 4.16.122.

 

1    Release Notes (4.17.46)

1.1    New Features & Enhancements 

-    Storage and Backup

  • Battery commissioning wizard for SolarEdge Home Battery 400V via SolarEdge Home Network
    • The wizard includes step by step multi-inverter multi-battery association, upgrade, configurations, testing, and backup settings (Backup enable and Backup Reserve level)
  • SolarEdge Home Backup Interface (BUI) added to the Device Manager screen with following capabilities:
    • Auto discover the BUI
    • Add BUI device page with More info page and Remove device button
    • No Communication troubleshooting page (if communication with the BUI is lost)
    • Disable Backup menus when BUI is removed
  • SolarEdge Home Hub 1ph inverters with SolarEdge Home Battery 400V and SolarEdge Home Backup Interface support AC coupling with SolarEdge Home Wave inverters with PV
    • The battery charges from the PV only inverter solar production both in on-grid and off-grid
    • This system configuration requires enabling Grid Charge
    • When configured to MSC, all battery charging is done from the PV inverter and only intermittent maintenance charge is done from the grid
    • Known limitation: in backup, when load <250W, the battery stops charging from the PV inverter
       

-    Safety

  • Improved SolarEdge Sense Connect performance 
     

-    Communications

  • SolarEdge Home Network link quality analysis and channel selection
  • Add Wi-Fi channels 12-13 support
  • Display inverter’s Wi-Fi client IP when connected to Monitoring via Wi-Fi router


-    Grid & Power Control

  • P(f) mode 7 UI updated:
Grid & Power Control

 

 

Frequency Ride Through (FRT) UI update:

  • Enable selecting the FRT mode
  • Showing FRT-K factor only for FRT modes 1 & 5
Frequency Ride Through (FRT) UI update
  • (Australia only) Hide all AUS except for AS4777:2020 grid codes
  • (Japan Only) AC Socket Over Voltage and Under Voltage settings view and edit enabled for SE5500H-JPJ with AC-Socket

2.   Firmware package for SetApp enabled inverters

Table 2: Inverters' firmware versions

Product CPU DSP1 DSP2 Additional
SolarEdge Home Wave inverter- single phase (w/wo Storage I/F, EVSE) 4.17.46 1.0.1614 / 1.100.1421 2.0.1305 / 2.100.1302

EVSE:
1.51.0

SolarEdge Home Hub inverter- single phase 4.17.46 1.0.1517 / 1.100.1324 2.0.1305 / 2.100.1302 N/A
Single Phase Inverter with HD-Wave Technology and AC Socket (JET) 4.17.46 1.1.58 2.2.34

AC Socket:
0.0.34

Three Phase Residential Inverter 4.17.46 1.13.2018 / 1.20.1230 2.19.1602 / 2.20.906 N/A
Three Phase Residential Booster Inverter

DSP3:
0.3.4

 

 

Table 3: Devices' firmware versions

Product CPU Controller
Smart EV Charger 4.16.25 2.2.10
Energy Meter N/A 0.78 / 0.1080 / 0.2009.0
Smart Energy Hot Water 3.10042 0.12.110
SolarEdge Home Backup Interface N/A

0.1.82 /
1.0.32

SolarEdge Home Inline Meter – Three Phase N/A 1.0.32
SolarEdge Home Network module (NCP) N/A 1.0.16

Table 4: Batteries’ firmware versions

Battery controller Version
SolarEdge Home Battery SMCU 1.0.66 
SolarEdge Home Battery  DCDC 0.0.79 / 1.0.26 
SolarEdge Home Battery BMS 0.6.5

 

  Battery controller ID Version
LG RESU LG RESU10H DCDC

5010/7010

5020/7020

5.4.6

5.4.8

LG RESU10H BMS 100 1.4.6.0
LG RESU Prime LG RESU10H Prime DCDC 1010 1.2.5/1.2.18
LG RESU16H Prime DCDC 1610
LG RESU10H/16H Prime BMS 0 2.4.2.4

3    Release Notes (4.16.122 for 3ph StorEdge)

3.1    New Features & Enhancements

  • Support up to 5 battery modules
  • Add lock state to SolarEdge Home Battery 48V in case of extreme measurements and manually release from lock
  • Support multi-inverter and AC coupled installations
  • Remove "Communication Enhancement" menu item

3.2    Known issues and limitations

  • On AC coupled systems – mode 1 and 2 won’t work and should not be configured
  • In case there is communication problem between battery modules: 
    • Battery is functioning as expected – no implication to end user
    • Self-test will pass
    • Alert to installer is not implemented
  • “Export limit = 0” (AKA SL0) won’t work on AC coupled systems 
    • Implication on end user – excess PV won’t charge the battery
  • On monitoring: Energy decrease while battery is charging
    • No effect on end user – just wrong presentation on monitoring
  • On low SoC, there are un-necessary force charge events 
    • Occurs on less than 0.5% of installations
    • Implication on homeowner – No implications
  • DCDC upgrade may fail when a meter (models below) is connected. In case it fails to upgrade, there is a need to disconnect the meter, upgrade the DCDC again and then reconnect the meter
    • On Wattnode meter – always
    • On other meters – very rare, less than 0.1%
  • Battery module on follower inverter will charge/discharge even when communication loss with Master 
    • Inverter works independently and not as a whole site Msc

3.3    Resolved issues

  • Sub Giga bug was fixed, no need to change param 430 after installation      
  • Part number and manufacturer fix on monitoring  
  • DCDC and BMS upgrade issues
  • 5th and 4th module upgrade issues
  • Battery stops charging at 70%
  • CB trip issues
  • Sites with stuck packets
  • Derating power at Max SoE

 

4.    Firmware package for SetApp enabled inverters

Table 2: Inverters' firmware versions

Product CPU DSP1 DSP2 Additional
Three Phase StorEdge Inverter 4.16.122 1.20.1230 /1.13.2011 2.20.903 / 2.19.1602

DCDC:
2.2.132

 

 

Table 4: Batteries’ firmware versions

Battery controller Version
SolarEdge Home Battery 48V BMS 1.1260.0