Supported Non-SolarEdge External Devices | SolarEdge
Close mobile menu

Supported Devices

Supported Non-SolarEdge External Devices

 

  

Meters

SolarEdge offers Modbus meters that can be used for production / consumption / import / export monitoring; for additional info refer to the meter page. In addition, SolarEdge supports the connection of some external one- or three-phase revenue meters. The SolarEdge device reads the energy data from the energy meter and sends it to the SolarEdge monitoring portal.
 
An external meter can be connected to a SolarEdge inverter or to a Control and Communication Gateway. The following meters are supported:
 

Meter Model

MID approved

Supported Functionality

Min. Required SolarEdge Device CPU Firmware version

Comments

Inepro® PRO75D MODBUS

Yes

Production / Consumption monitoring

 

2.348

 

Inepro® PRO1250D MODBUS

Yes

Production / Consumption monitoring

 

2.348

 

Inepro® 0254 PRO1-Mod with version 1.18 and above

yes

Production / consumption / import / export monitoring

Export Limitation

3.1808

 

Inepro® 0268 PRO1-Mod

No

Production / consumption / import / export monitoring

Export Limitation

 

 

Inepro® 0.257 PRO380 with version 1.18 and above

yes

Production / consumption / import / export monitoring

Export Limitation

3.1808

 

Inepro® 0271 PRO380-Mod

No

Production / consumption / import / export monitoring

Export Limitation

 

 

Janitza® UMG 104 Power Analyzer

No

Production/Consumption / Import / Export monitoring

Export Limitation

For CCG from 3.2228

For Inverters from 4.12.xxx

 

Janitza® UMG 604 Power Analyzer

No

Production/Consumption / Import / Export monitoring

Export Limitation

For CCG from 3.2228

For Inverters from 4.12.xxx

In order to use Janitza 604 in Delta (and specifically in Aron Circuit) topology the following configuration need to be done in the Meter: In Register 110 we need to change the value from 0x0 to 0x1

S0 meter (with 250 to 10000 pulses per kWh)

No

Import

2.xxxx

 

Schneider iEM3255

Yes

Production/Consumption / Import / Export monitoring

4.19 or later

Not supported in Delta topology

*All the meters in the table were not tested and are not certified for G100 issue 2 amendment 2

For detailed information on how to connect and configure these meters to SolarEdge products, refer to: 

Connecting a Revenue Grade Meter to SolarEdge Devices application note

 

Environmental Sensors

SolarEdge offers environmental sensors that can be used to monitor a site’s irradiance, temperature and wind velocity and calculate site performance ratio; for additional info refer to the sensors page. In addition, SolarEdge supports the connection of other sensors.
The sensors connect to the SolarEdge Control and Communication Gateway (CCG).
 
SolarEdge has specifically tested and approved the sensors detailed in the table below, manufactured by 'Ingenieurbüro Mencke & Tegtmeyer GmbH'. However, any sensor that meets the analog sensor input specifications of the CCG can be used (refer to the CCG datasheet for full specifications).
 

Sensor Type

Model

Measurement Range

Electrical Output

Module Temperature

 

 

Tm-I-4090

-40…+90 °C

4..20 mA

Tm-V-4090

-40…+90 °C

0..10 V

Ambient Temperature

Ta-I-4090

-40…+90 °C

4..20 mA

Ta-V-4090 -40…+90 °C 0..10 V
Wind direction 4.3129.00.141 0…360° 4….20mA
4.3129.00.167 0…360° 0-2VDC
Wind Velocity
4.3519.00.167 0…50m/s 0-2VDC
Silicon Irradiance Sensor Si-I-420TC 0…1500W/m2 4….20mA
Si-V-10TC 0…1500W/m2 0-10VDC
Pyranometers SMP11-A 0…1600W/m² 4….20mA
SMP11-V -200…2000W/m² 0-1VDC